YCB扁电缆

发布日期 :2024-01-15 13:38 编号:4823559 发布IP:49.82.57.83
供货厂家
江苏春晨电缆有限公司  
品牌
春晨
50
35
25
33
20
18
报价
10.00元/米
起订
100 米
库存
1000 米
发货时间
3 天内
联系人
赵礼春(先生)
电话
13770439971
手机
18951262418
询价邮件
843499471@qq.com
区域
淮安电气用电缆
地址
江苏省金湖县金南幸福路
在线咨询:
点击这里给我发消息
让卖家联系我
详细介绍
手机版链接:https://m.trustexporter.com/cz4823559.htm


江苏春晨电缆有限公司生产YCB扁电缆,主令操纵电器元件及整定电器元件的布置应避免由于偶然触及其手柄、 按钮而误动作或动作值变动的可能性, 整定装置一般在整定完成后应以双螺母锁 紧并用红漆漆封,以免移动。
The arrangement of the main order control electrical components and the setting electrical components should avoid the possibility of accidental contact and the change of the handle, button, or action value. The setting device should be locked with a double nut and sealed with a red lacquer to avoid moving after the completion of the setting.YCB扁电缆
8. 熔断器、 使用中易于损坏、 偶尔需要调整及复位的零件, 应不经拆卸其他部件便可以接近,以便于更换及调整。
8. fuses, parts that are easy to be damaged in use and occasionally need to be adjusted and reset, can be accessible without removing other components for easy replacement and adjustment.
9. 熔断器安装位置及相互间距离应便于熔体的更换。YCB扁电缆
9. installation position and distance between fuses should facilitate replacement of melts.
10. 不同电压等级的熔断器要分开布置,不能交错混合排列,有熔断指示器的熔断器,其指示器应装在便于观察的一侧,低压断路器与熔断器配合使用时,熔断器应安装在电源侧。
10. the fuse of different voltage levels should be arranged separately, not interlaced and mixed, and a fuse with a fuse indicator. The indicator should be mounted on one side of the convenient observation. The fuse should be installed on the power side when the low voltage circuit breaker is used in conjunction with the fuse.
11. 强弱电端子应分开布置; 当有困难时, 应有明显标志并设空端子隔开或 设加强绝缘的隔板。
11. the strong and weak terminals should be separately arranged. When there are difficulties, there should be clear signs and partitions with the isolation of terminals or reinforcement.
12. 端子应有序号, 端子排应便于更换且接线方便; 离地高度宜大于 350mm 。
The 12. terminals should have serial numbers. The terminal block should be convenient to replace and convenient to connect. The height of the ground should be larger than 350mm.
13. 有防震要求的电器应增加减震装置,其紧固螺栓应采取防松措施。
13. electrical appliances with shockproof requirements shall increase shock absorbers, and the fastening bolts shall be loosened.
14. 新落料的导轨端头处均需剪斜口,以防工作时的意外。
14. the new ends of the guide rails should be cut at the ends to prevent accidents at work.
15. 线槽应平整、无扭曲变形,内壁应光滑、无毛刺,线槽接口应平直、严密,槽盖应齐全、平整、无翘角。
The 15. line grooves should be smooth and without distortion. The inner wall should be smooth and burr free. The interface of the line slot should be straight and tight, and the groove cover should be complete, smooth and without warping angle.
16. 线槽的连接应连续无间断。每节线槽的固定点不应少于两个。在转角、 分支处和端部均应有固定点,并紧贴墙面固定。
YCB扁电缆The connection of the 16. wire grooves should be continuous without interruption. There should be no less than two fixed points for each slot. The corners, branches and ends should be fixed and firmly attached to the wall.
17. 线槽敷设应平直整齐,水平或垂直允许偏差为其长度的 2‰,全长允许 偏差为 20mm 。并列安装时,槽盖应便于开启。
The 17. line grooves should be straight and neat, with a horizontal or vertical allowable deviation of 2 per thousand, and the total allowable deviation is 20mm. The groove cover should be easy to open when it is installed side by side.
18. 接触器和热继电器的接线端子与线槽直线距离 30mm ,其他载流元件与线槽直线距离 30mm 。
18. the terminals of the contactor and the thermal relay are straight away from the line slot 30mm, and the other current carrying elements are straight away from the line slot 30mm.
19. 控制端子与线槽直线距离 20mm ,动力端子与线槽直线距离 30mm 。
19. control terminal and line slot straight distance 20mm, power terminal and line slot straight distance 30mm.
20. 中间继电器和其他控制元件与线槽直线距离 20mm 。
20. the intermediate relay and other control elements are straight away from the line slot 20mm.